24hrs Ambulatory Blood Pressure Monitor Spo2 Monitor Analysis Software oximeter
Introduction
PM50 is a multi-functional patient monitor  that can monitor BP and SpO2 at the same time. Realizing long time monitoring of  dynamic blood pressure, the device is widely applicable to hospital wards,  community clinics and other medical institutions.
Functions
Features:
1)Compact and portable, easy  to use.
2)With Integrative SpO2 Probe.
3)Double working modes,monitoring  function and 24 hours ambulatory NIBP measurement function can be flexibly  set.
4)Long time monitoring BP and SpO2, displaying value of BP, SpO2 and  PR.
5)NIBP and SpO2 data Record for large capacity.
6)With friendly user  interface, the user can see list menu and review measurement results.
7)The  device can display low power information, alarm information, error information  and time information richly.
8)Parameter alarms function is  optional.
9)Patient information can be flexibly set.
10)Case management  function.PC software can achieve data review, analysis measurement results,  seeing trend, printing reports and other functions.
11)Data can be  transmitted between device and computer, such as upload patient information,  download measurement data.
12)English and Chinese menu.
Function of master  device software:
1)Set patient information through PC software.
2)Up to  1000 patients cases can be edited and supervised.
3)The time segment of  dealing with the patient’s NIBP data is 48 hours.
4)Connect the device by USB  interface.
5)Can upload patient information data collection project and  download collection data.
6)Can display scoop-shape trend graph,filling-type  trend graph, histogram, pie chart, correlation line graph.
7)Can edit every  piece of data, and add annotation to it.
8)Can edit basic  information,doctor's advice information, NIBP and SpO2 status instruction,  current medicine-taken information, etc.
9)Support print preview,print the  report.
Performance
NIBP:
Measurement Method:  Oscillometry
Measurement Mode: The upper arm measure
Measuring range:
SYS   40mmHg~270mmHg
MAP  20mmHg~235mmHg
DIA    10mmHg~215mmHg
Automatic Measurement Interval: 5.10.15.20.30.45.60.90.120  minutes
Resolution: 1mmHg
Accuracy: ±3mmHg
Increasing pressure mode:  force pump increases pressure automatically
Reducing pressure mode:  self-motion ladder reducing pressure mode
Alarm parameter: SYS /  DIA
SpO2:
Measuring range: 0%~100%
Resolution:1%
Accuracy:  70-100%, ±2%, below 70% unspecified
Error in Weak Filling Condition:SpO2 and  pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error  is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to  surrounding light:The deviation between the value measured in the condition of  man-made light or indoor natural light and that of darkroom is less than  ±1%.
Pulse Rate:
Measuring  range:30bpm~250bpm
Resolution:1bpm
Accuracy: ±2 bpm or ±2% (select larger)
Display:
2.4" TFT colour LCD
Safety:
Power: DC 3V(Two "AA",1.5V  Alkali Battery)
Product safety type:Type BF application part (Internally  powered,defibrillator protected)
Accessories
cuff for adult
Integrative SpO2  Probe
USB data line
PC software
Pouch
User manual
Physical  characteristic
Dimension: 128*69*36 mm (No including  Packing)
Weight: <350g (Including Batteries)
Working  environment:
Temperature:5 ˚C~40 ˚C
Relative  humidity:≤80%
Altitude:-500 to 4,600m (-1,600 to 15,000ft)
Specific EMC,  climate, mechanical environment: Do not use a mobile phone in the vicinity of  the patient monitor for the strong radiation field produced by  mobile phone  would interfere with the normal function of the patient monitor use.
Storage  environment:
Temperature: -20˚C ~ 60 ˚C
Relative humidity: ≤95  %
Altitude:-500 to 13,100m (-1,600 to 43,000ft)
Specific EMC, climate,  mechanical environment: The patient monitor after packaged should be stored in a  well-ventilated room with no corrosive gas. Strong shock, vibration and snow and  rain should be avoided during transportation.