Description
3-parameter Vital Sign Patient Monitor NIBP Spo2 Pulse Rate Machine, CEI
ntroduction
Introduction
CMS5000 Patient Monitor adopts Oscillometry technology, also called Oscillography technology for NIBP measuring,
and adopts Photoelectric Oxyhemoglobin Inspection Technology combining Capacity Pulse Scanning & Recording
Technology for SpO2 measuring. Systolic Pressure (SYS), Diastolic Pressure (DIA), Mean Pressure (MAP), SpO2
and Pulse rate (PR) can be accurately measured.
Compact appearance, comprehensive functions, simple and convenient operation, which is applicable for hospitals,
community medical treatment and family.
Features
Be applicable for NIBP and SpO2 monitoring of adult, pediatric and neonate of all ages, easy operation and high cost
performance.
Be applicable for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics.
Built-in rechargeable lithium polymer battery for uninterrupted monitoring.
Compact and flexible appearance, easy for carrying and be suitable for indoor and outdoor(in ambulance) monitoring.
With user-friendly interface.
Display with 2.4'' (320×240) color TFT LCD and blue highlight LED.
Visual and audible alarm for Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse
rate(PR), and upper and lower limit of alarm can be set.
Unique Flash memory, storage for up to 2000 NIBP data or SpO2 data within 48-hour.
Convenient and quick in inquiring measurement data.
Optional parameter: temperature.
Performance
NIBP monitoring
Measurement method: Oscillometry
Measurement mode: manual/auto.
Auto measurement interval: adjustable from 1 to 255 minutes.
Resolution: 1mmHg.
Accuracy: Maximum Mean deviation±5mmHg, Maximum Standard deviation≤8mmHg.
Self-check function.
Overpressure protection: double protection for software and hardware.
1.Monitoring range
Adult:
SYS: 40mmHg~270mmHg;
MAP: 20mmHg~235mmHg;
DIA: 10mmHg~215mmHg;
Pediatric:
SYS: 40mmHg~200mmHg;
MAP: 20mmHg~165mmHg;
DIA: 10mmHg~150mmHg;
Neonate:
SYS: 40mmHg~135mmHg;
MAP: 20mmHg~110mmHg;
DIA: 10mmHg~100mmHg;
2.Upper and lower limits of alarming
Adult:
SYS: 40mmHg~270mmHg;
MAP: 20mmHg~235mmHg;
DIA: 10mmHg~215mmHg;
Pediatric:
SYS: 40mmHg~200mmHg;
MAP: 20mmHg~165mmHg;
DIA: 10mmHg~150mmHg;
Neonate:
SYS: 40mmHg~135mmHg;
MAP: 20mmHg~110mmHg;
DIA: 10mmHg~100mmHg。
SpO2 monitoring
Continuous real-time measuring.
Adopt digital SpO2 technology, which has strong anti-interference capability.
Real-time display SpO2, pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate (PR) trend graph.
Trend graph with the function of adaptive scaling
Standard adult finger-clip probe, binding probe for neonate is optional.
1.SpO2 Measuring
Range: 0%~100% (Resolution: 1%)
Accuracy: ±2% in stage of 70%-100%, and unspecified in stage of less than 70%.
2.Pulse Rate Measuring
Range: 30bpm~250bpm(Resolution: 1bpm)
Accuracy: ±2bpm or ±2%, whichever is greater.
3.Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling
ratio is 0.4%, SpO2 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever is greater.
4.Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or
indoor natural light and that of darkroom is less than ±1%.
Accessories
Power cord
SpO2 probe
Adult BP cuff
Extending tube for blood pressure
Physical characteristic
Dimension: 232 mm(L)×198 mm(W)×75 mm(H)
Weight: 1.15kg
Buy Safe Product!
The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item.
Shipment
1. We will ship the item within 48 hours after receiving your payment, please kindly leave your detail shipping address and telephone
number, both are very important for the shipment,thank you.
2.We will upload the tracking number after shipment,you can search from both ebay and paypal.You can track online.
3. If you haven't received the item after 2 weeks of your payment, please contact me immediately!
Terms of Sale
1.If you have a defective item, you want to return or discount. Please contact us within 14 days from you receive the shipment.All return
items must be returned with it's original packaging and accessories. Customer is responsible for shipping charges on returned items.
2.we will refund the money to you when we get the return items. Or replace item for you. We will deal with the refund in 2 business days when we get the info from
you.Please read our trade Policy before buy , if you don't agree our trade policy please don't buy it.
International Buyer--Please note:
Import duties,Taxes are not included in the item price.These charges are buyers' responsibility
We are the manufacturer of medical equipment for 17 years, the following are our main products:
ECG / ECG holter EEG / EEG Holter B-ultrasound
Patient Monitor Fetal doppler Fetal Monitor
Spo2 Monitor Stethoscope Medical Image....
Agent in the world!
We are look for partners in the world now!
Do you want to become our agent in you conutry?
Join US!
Skype:xuebox3
contec.med.mary # hotmail dot com
Only English User Manual,Please contact us if you need other language version.thank you